Motor Control Training Equipment

Motor Control Training Equipment

DLWD-DJ22-M Induction Machine Training System

Share:

Model:DLWD-DJ22-M Induction Machine Training System

1.Input voltage Three-phase five-wire system 380V±10% 50HZ

2.Working environment Ambient temperature range is -5~40℃

3.Device capacity AC: <1.5KVA

 DC excitation power supply: <0.5A

 Armature power supply: <2A

4.Dimensions length × width × height = 1810x720x1620mm3

5.Technical parameters of the training platform:

 input voltage three-phase five-wire system 380V±10% 50HZ

 Working environment The ambient temperature range is -5~40℃

 device capacity AC <1.5KVA

6.The total power supply control has a leakage protection function. When the leakage current reaches 30mA, the protection device will operate.


DLWD-DJ22-M Induction Machine Training System
DLWD-DJ22-M Induction Machine Training System
DLWD-DJ22-M Induction Machine Training System

Details introduction

Equipment Overview

DLWD-DJ22-M Induction Machine Training System is one basic training system for electrical machine. It is widely used in the Electrical engineering laboratories. This motor training kits includes DC motor, AC motor, single-phase transformer and three-phase transformer and their control and operation circuits. The equipment has established a teaching and training system to measure voltage, current, torque, speed, and mechanical power.

Equipment Features

1.There are three 450V pointer AC voltmeters for grid voltage indication.

2.AC power supply:

Provide three-phase power output

0~220V/2A adjustable AC power output

Transformer AC output; the equipment has an emergency stop button, which immediately cuts off the three-phase power output when pressed.

3.DC power supply:

Provide DC24V DC power supply, and is equipped with DC instrument display, the accuracy level is 1,

Provide 0~200V/2A adjustable DC power supply.

Provide fixed DC220V power output

4.Measuring instruments:

 AC voltmeter: accuracy level 1.0; measuring range 0~500V

 AC ammeter: measuring range 0~5A, precision 0.5 grade;

 AC three-phase power meter: measuring range 0-1.2KW, accuracy level 1.0

 AC single-phase power meter: measuring range 0-0.4KW, accuracy level 1.0

 AC frequency meter: measuring range 45-55Hz, accuracy level 1.0

 AC power factor meter: measuring range: ±0.5-1.0, accuracy level 1.0

 DC digital ammeter: measuring range 0~3A, three-and-a-half digit display, input impedance 10MΩ, precision 0.5;

 One DC digital voltmeter: measuring range 0-450V, three-and-a-half digit display, input impedance 10MΩ, precision 0.5;


Training Projects

-How to set the parameters of the frequency conventer

-Experiment of External Terminal Control Based on Frequency Converter

-Motor forward and reverse experiment controlled by reversing switch

-Using Star-Delta Starter to Realize Motor Star-Delta Starting

-Combined switch control two-speed motor experiment

-Self-locking experiment of motor controlled by contactor

-Motor forward and reverse experiment with contactor interlocking

-Double chain motor forward and reverse experiment

-Star-Delta Starting Experiment of Contactor Control

-Star-Delta Experiment of Time Relay Switching

-Three-phase motor sequential start

-Single-phase capacitor motor starting experiment

-Single-phase capacitor motor forward and reverse experiment

-Single-phase resistance motor forward and reverse experiment

-DC servo experiment

-How to use the torque sensor


Get In Touch

Contact Us

Focus on customers and become a long-term and large-scale international enterprise

TOP